General information |
|
|
Name |
Neumarkter Lammsbräu
|
|
Country installed |
Germany
|
|
Address |
Neumarkt/Oberpfalz
|
|
Industry sector, NACE code |
C11 - Manufacture of beverages
|
|
Solar thermal system owner / operator |
Neumarkter Lammsbräu Gebr. Ehrenspreger e.K.
|
|
Solar thermal engineering company |
Grammer Solar GmbH
|
|
Process integration engineering company |
Simon Klimatechnik GmbH
|
|
Year of operation start |
2000
|
|
|
Technical parameters |
|
|
Collector technology |
air collector
|
|
Collector name |
|
|
Installed collector area (gross), m² |
72.5
|
|
Installed collector area (aperture), m² |
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
50.75
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
air
|
|
Solar energy storage |
no solar energy storage
|
|
Storage volume, m³ |
1
|
|
Kind of conventional heat source |
|
|
Kind of fuel used |
|
|
|
Process |
|
|
Solar thermal energy used for |
Pre-heating the ambient air for the drying process in the malthouse
|
|
Unit operation |
drying
|
|
Point of Solar Heat Integration |
B2) Heating of process medium (please specify)
|
|
--> Integration how and where |
|
|
--> Temperature range process |
up to 60 °C air temperature
|
|
--> Temperature range solar loop (min/max), C° |
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
32,000.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
no subsidies
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
25
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
441.38
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
12 years of operating experience and 12 years without problemes and maintenances.
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Rudolf Ettl
|
|
Company of author |
Grammer Solar
|
|
E-mail |
r.ettl@grammer-solar.de
|
|
Phone |
09621-30857-13
|
|
Homepage |
http://www.grammer-solar.com
|
|
|
|
|
|
|
|
|
|