General information |
|
|
Name |
Rongxing meat and poultry processing
|
|
Country installed |
China
|
|
Address |
Rongcheng City, Shandong Province
|
|
Industry sector, NACE code |
C10.1 - Processing and preserving of meat and production of meat products
|
|
Solar thermal system owner / operator |
Shandong Sunshine Solar Energy Engineering Co., Ltd.
|
|
Solar thermal engineering company |
Shandong Sunshine Solar Energy Engineering Co., Ltd.
|
|
Process integration engineering company |
|
|
Year of operation start |
2021
|
|
|
Technical parameters |
|
|
Collector technology |
evacuated tube collector
|
|
Collector name |
All-glass vacuum tube collector
|
|
Installed collector area (gross), m² |
1018.4
|
|
Installed collector area (aperture), m² |
668.66
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
712.88
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
water
|
|
Solar energy storage |
short-term water storage
|
|
Storage volume, m³ |
40
|
|
Kind of conventional heat source |
other
|
|
Kind of fuel used |
|
|
|
Process |
|
|
Solar thermal energy used for |
Used for hot water requirement of processing workshop
|
|
Unit operation |
other process heating
|
|
Point of Solar Heat Integration |
B2) Heating of process medium (please specify)
|
|
--> Integration how and where |
|
|
--> Temperature range process |
55~60
|
|
--> Temperature range solar loop (min/max), C° |
60~80
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
176,361.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
134512
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
298917
|
|
Others (excl. VAT), € |
119567
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
1
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
20
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
173.17
|
|
Solar fraction, % |
75
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Zheng Ruicheng
|
|
Company of author |
China Academy of Building Research
|
|
E-mail |
zhengrc@vip.sina.com
|
|
Phone |
|
|
Homepage |
|
|
|
|
|
|
|
|
|
|