General information |
|
|
Name |
DOPPELT IDHELIO
|
|
Country installed |
France
|
|
Address |
FRUIT GOURMET le Prégay 47800 Allemans du Dropt FRANCE
|
|
Industry sector, NACE code |
C10.3 - Processing and preserving of fruit and vegetables
|
|
Solar thermal system owner / operator |
FRUIT GOURMET SAS
|
|
Solar thermal engineering company |
IDHELIO
|
|
Process integration engineering company |
IDHELIO
|
|
Year of operation start |
2019
|
|
|
Technical parameters |
|
|
Collector technology |
fresnel collector
|
|
Collector name |
HELIO PROD
|
|
Installed collector area (gross), m² |
360.0
|
|
Installed collector area (aperture), m² |
200.0
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (actual), kWth |
108.0
|
|
Solar collector loop heat transfer fluid |
air
|
|
Solar energy storage |
other
|
|
Storage volume, m³ |
16
|
|
Kind of conventional heat source |
other
|
|
Kind of fuel used |
other
|
|
|
Process |
|
|
Solar thermal energy used for |
drying / pasteurizing
|
|
Unit operation |
drying
|
|
Point of Solar Heat Integration |
B2) Heating of process medium (please specify)
|
|
--> Integration how and where |
replacing propane gas flame producing hot air for drying / pasteurazing
|
|
--> Temperature range process |
85 - 95 °C
|
|
--> Temperature range solar loop (min/max), C° |
250°C for pebble bed storage
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
160.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
80%
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
0.44
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
IDHELIO
|
|
Integration methodology |
adding only an hot air entry into the drying oven to replace propane heated air : hot air comes from the pebble heat storage supplied by fresnel collectors.
batch process on a daily basis : it is solar operated when the heat storage contains enough energy
|
|
Crucial Interfaces |
mixing chamber to produce process air at 85°C starting from 250°C stored heat
short distance from storage (outside from workshop) and oven (inside the workshop)
mirror geometry (large radius of curvature parabolic mirrors)
|
|
Construction / Commissioning |
installed as shadehouse over company car and lorry park
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Levaillant Christophe
|
|
Company of author |
IDHELIO
|
|
E-mail |
christophe.levaillant@idhelio.com
|
|
Phone |
+33673108221
|
|
Homepage |
www.idhelio.com
|
|
|
|
|
|
|
|
|
|