General information |
|
|
Name |
Juice manufacturer in Limassol
|
|
Country installed |
Cyprus
|
|
Address |
Limassol, Cyprus
|
|
Industry sector, NACE code |
C10.3 - Processing and preserving of fruit and vegetables
|
|
Solar thermal system owner / operator |
Protarget AG
|
|
Solar thermal engineering company |
Protarget AG
|
|
Process integration engineering company |
|
|
Year of operation start |
2020
|
|
|
Technical parameters |
|
|
Collector technology |
evacuated tube collector
|
|
Collector name |
CPC
|
|
Installed collector area (gross), m² |
225.0
|
|
Installed collector area (aperture), m² |
225.0
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
157.5
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
|
|
Solar energy storage |
short-term water storage
|
|
Storage volume, m³ |
|
|
Kind of conventional heat source |
|
|
Kind of fuel used |
|
|
|
Process |
|
|
Solar thermal energy used for |
Water preheating
|
|
Unit operation |
pasteurization
|
|
Point of Solar Heat Integration |
A1) Heating of make-up water
|
|
--> Integration how and where |
|
|
--> Temperature range process |
|
|
--> Temperature range solar loop (min/max), C° |
75 °C up to 150 °C
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
61,250.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
61250
|
|
Subsidy, € or % of total investment costs |
na
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
178
|
|
Specific annual useful solar heat delivery, MWh/am² |
0.79
|
|
Specific investment costs, €/m² |
272.22
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
The Compound Parabolic Concentrator (CPC) based evacuated tube collectors, equipped with a thermocline TES, is providing pre heating to the boiler feed-water of a F&B company. The solar system starts providing heat from early moring 04:00 hr till the evening
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Daria Gablitschka
|
|
Company of author |
Protarget AG
|
|
E-mail |
gablitschka@protarget-ag.com
|
|
Phone |
|
|
Homepage |
https://protarget-ag.com/
|
|
|
|
|
|
|
|
|
|