General information |
|
|
Name |
Jinan, Shanddong pre-heating for industrial boiler
|
|
Country installed |
China
|
|
Address |
Jinan, Shandong
|
|
Industry sector, NACE code |
C - Manufacturing
|
|
Solar thermal system owner / operator |
Linuo Paradigma
|
|
Solar thermal engineering company |
Linuo Paradigma
|
|
Process integration engineering company |
Linuo Paradigma
|
|
Year of operation start |
2010
|
|
|
Technical parameters |
|
|
Collector technology |
evacuated tube collector
|
|
Collector name |
CPC 1518, medium-temperature solar collector
|
|
Installed collector area (gross), m² |
5892.0
|
|
Installed collector area (aperture), m² |
5184.0
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
4124.4
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
water
|
|
Solar energy storage |
steam accumulation tank
|
|
Storage volume, m³ |
20
|
|
Kind of conventional heat source |
steam boiler
|
|
Kind of fuel used |
coal
|
|
|
Process |
|
|
Solar thermal energy used for |
preheating for steam
|
|
Unit operation |
general process heating
|
|
Point of Solar Heat Integration |
A3) Heating of supply heat storage
|
|
--> Integration how and where |
|
|
--> Temperature range process |
80-150
|
|
--> Temperature range solar loop (min/max), C° |
80-95
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
540,000.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
30% subsidy
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
91.65
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Erica Shan
|
|
Company of author |
Linuo Paradigma/Linuo Ritter International
|
|
E-mail |
shangl@linuo-ritter-international.com
|
|
Phone |
0086-18953198532
|
|
Homepage |
www.linuo-ritter-international.com
|
|
|
|
|
|
|
|
|
|