General information |
|
|
Name |
KEMET Electronics Portugal, S.A.
|
|
Country installed |
Portugal
|
|
Address |
Rua Werner Von Siemens, 1, Évora, 7005-639 ÉVORA
|
|
Industry sector, NACE code |
C27 - Manufacture of electrical equipment
|
|
Solar thermal system owner / operator |
KEMET Electronics Portugal, S.A.
|
|
Solar thermal engineering company |
MCG Solar
|
|
Process integration engineering company |
Project SHIP (INEGI + University of Évora + Kemet + MCG Solar + OnControl)
|
|
Year of operation start |
2019
|
|
|
Technical parameters |
|
|
Collector technology |
other or various collectors
|
|
Collector name |
QS-CPC MCG
|
|
Installed collector area (gross), m² |
276.0
|
|
Installed collector area (aperture), m² |
185.0
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (actual), kWth |
104.0
|
|
Solar collector loop heat transfer fluid |
thermo-oil
|
|
Solar energy storage |
other
|
|
Storage volume, m³ |
1
|
|
Kind of conventional heat source |
other
|
|
Kind of fuel used |
other
|
|
|
Process |
|
|
Solar thermal energy used for |
Electrolyte preparation
|
|
Unit operation |
general process heating
|
|
Point of Solar Heat Integration |
B1) Heating of process(es) / process vessel(s)
|
|
--> Integration how and where |
|
|
--> Temperature range process |
40 - 180
|
|
--> Temperature range solar loop (min/max), C° |
60 - 180
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
222,442.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
66%
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
805.95
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Ricardo Pereira
|
|
Company of author |
MCG Solar
|
|
E-mail |
ricardo.pereira@mcg.pt
|
|
Phone |
+351914142621
|
|
Homepage |
http://www.mcg.pt/en/
|
|
|
|
|
|
|
|
|
|