General information |
|
|
Name |
Barcel S.A DE C.V.
|
|
Country installed |
Mexico
|
|
Address |
Mérida, Yucatán, Mexico
|
|
Industry sector, NACE code |
C10 - Manufacture of food products
|
|
Solar thermal system owner / operator |
|
|
Solar thermal engineering company |
INVENTIVE POWER SAPI DE CV
|
|
Process integration engineering company |
INVENTIVE POWER SAPI DE CV
|
|
Year of operation start |
2017
|
|
|
Technical parameters |
|
|
Collector technology |
parabolic trough collector
|
|
Collector name |
Power Trough 250
|
|
Installed collector area (gross), m² |
529.2
|
|
Installed collector area (aperture), m² |
176.8
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (actual), kWth |
77.9
|
|
Solar collector loop heat transfer fluid |
thermo-oil
|
|
Solar energy storage |
other
|
|
Storage volume, m³ |
0.15
|
|
Kind of conventional heat source |
other
|
|
Kind of fuel used |
natural gas
|
|
|
Process |
|
|
Solar thermal energy used for |
Vegetal oil heating
|
|
Unit operation |
cooking
|
|
Point of Solar Heat Integration |
B2) Heating of process medium (please specify)
|
|
--> Integration how and where |
Heat transfer oil/Vegetal oil with Plate Heat exchanger
|
|
--> Temperature range process |
35/164
|
|
--> Temperature range solar loop (min/max), C° |
30/200
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
81,349.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
NO SUBSIDIES
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
153.72
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Angel Mejía Santiago
|
|
Company of author |
INVENTIVE POWER SAPI DE CV
|
|
E-mail |
angel.mejia@inventivepower.com.mx
|
|
Phone |
|
|
Homepage |
www.inventivepower.com.mx
|
|
|
|
|
|
|
|
|
|