General information |
|
|
Name |
Poultry Processing Malaysia PPNJ
|
|
Country installed |
Malaysia
|
|
Address |
PPNJ Poultry & Meat Sdn. Bhd. Simpang Renggam Johor Malaysia
|
|
Industry sector, NACE code |
C10.1 - Processing and preserving of meat and production of meat products
|
|
Solar thermal system owner / operator |
PPNJ, POULTRY AND MEAT SDN. BHD.
|
|
Solar thermal engineering company |
SIRIM INDUSTRIAL RESEARCH
|
|
Process integration engineering company |
SIRIM INDUSTRIAL RESEARCH
|
|
Year of operation start |
2017
|
|
|
Technical parameters |
|
|
Collector technology |
evacuated tube collector
|
|
Collector name |
HI-MIN HUJ3
|
|
Installed collector area (gross), m² |
181.35
|
|
Installed collector area (aperture), m² |
118.95
|
|
Installed collector area (absorber), m² |
95.55
|
|
Installed thermal power (actual), kWth |
163.2
|
|
Solar collector loop heat transfer fluid |
water
|
|
Solar energy storage |
short-term water storage
|
|
Storage volume, m³ |
8
|
|
Kind of conventional heat source |
steam boiler
|
|
Kind of fuel used |
other
|
|
|
Process |
|
|
Solar thermal energy used for |
scalding process
|
|
Unit operation |
blanching
|
|
Point of Solar Heat Integration |
B1) Heating of process(es) / process vessel(s)
|
|
--> Integration how and where |
Heating of process at scalding tank
|
|
--> Temperature range process |
70-75
|
|
--> Temperature range solar loop (min/max), C° |
80-90
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
90,400.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
66,800
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
10,000
|
|
Others (excl. VAT), € |
11,400
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
2,200
|
|
Subsidy, € or % of total investment costs |
80%
|
|
Cost for fuel replaced, €/MWhfuel |
90
|
|
Calculated solar thermal system life time, a |
15
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
498.48
|
|
Solar fraction, % |
80
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
MOHD FAISAL ZULKAPLI
|
|
Company of author |
SIRIM BERHAD, SIRIM INDUSTRIAL RESEARCH
|
|
E-mail |
mfaisalz@sirim.my
|
|
Phone |
+60355446560
|
|
Homepage |
www.sirim.my
|
|
|
|
|
|
|
|
|
|