General information |
|
|
Name |
Harita Seatings Systems Limited
|
|
Country installed |
India
|
|
Address |
Hosur - Thally Road, Hosur, Bagalkot - 587114, Belagondapalli
|
|
Industry sector, NACE code |
C30 - Manufacture of other transport equipment
|
|
Solar thermal system owner / operator |
Harita Seatings Systems Limited
|
|
Solar thermal engineering company |
Aspiration Energy
|
|
Process integration engineering company |
Aspiration Energy
|
|
Year of operation start |
2015
|
|
|
Technical parameters |
|
|
Collector technology |
evacuated tube collector
|
|
Collector name |
|
|
Installed collector area (gross), m² |
754.8
|
|
Installed collector area (aperture), m² |
|
|
Installed collector area (absorber), m² |
501.12
|
|
Installed thermal power (actual), kWth |
360.0
|
|
Solar collector loop heat transfer fluid |
water
|
|
Solar energy storage |
no solar energy storage
|
|
Storage volume, m³ |
|
|
Kind of conventional heat source |
other
|
|
Kind of fuel used |
other
|
|
|
Process |
|
|
Solar thermal energy used for |
cleaning automobile parts before painting
|
|
Unit operation |
cleaning
|
|
Point of Solar Heat Integration |
B1) Heating of process(es) / process vessel(s)
|
|
--> Integration how and where |
Erecting coil type heat ex-changer inside the process tanks
|
|
--> Temperature range process |
55-60 °C
|
|
--> Temperature range solar loop (min/max), C° |
70-95°C
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
191,200.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
26640
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
20 years
|
|
Annual useful solar heat delivery, MWh/a |
648
|
|
Specific annual useful solar heat delivery, MWh/am² |
0.86
|
|
Specific investment costs, €/m² |
253.31
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
Source |
|
|
Author |
Viji Suresh
|
|
Company of author |
Aspiration Energy
|
|
E-mail |
viji.suresh@aspirationenergy.com
|
|
Phone |
|
|
Homepage |
www.aspirationenergy.com
|
|
|
|
|
|
|
|
|
|