General information |
|
|
Name |
FASA Valladolid
|
|
Country installed |
Spain
|
|
Address |
Calle de Caamaño, 126 47013 Valladolid, España
|
|
Industry sector, NACE code |
C29 - Manufacture of motor vehicles, trailers and semi-trailers
|
|
Solar thermal system owner / operator |
FASA Renault
|
|
Solar thermal engineering company |
|
|
Process integration engineering company |
|
|
Year of operation start |
2007
|
|
|
Technical parameters |
|
|
Collector technology |
flat plate collector
|
|
Collector name |
Wagner Solar Euro C32 RH
|
|
Installed collector area (gross), m² |
243.6
|
|
Installed collector area (aperture), m² |
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
170.52
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
|
|
Solar energy storage |
short-term water storage
|
|
Storage volume, m³ |
15
|
|
Kind of conventional heat source |
steam boiler
|
|
Kind of fuel used |
natural gas
|
|
|
Process |
|
|
Solar thermal energy used for |
the solar thermal energy is used in the bodyworks sheet surface preparation for the weld ing process and before the painting
|
|
Unit operation |
surface treatment
|
|
Point of Solar Heat Integration |
B1) Heating of process(es) / process vessel(s)
|
|
--> Integration how and where |
|
|
--> Temperature range process |
50 °C
|
|
--> Temperature range solar loop (min/max), C° |
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
100,000.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
50000
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
|
|
Annual useful solar heat delivery, MWh/a |
128
|
|
Specific annual useful solar heat delivery, MWh/am² |
0.53
|
|
Specific investment costs, €/m² |
410.51
|
|
Solar fraction, % |
50
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
The solar heating system has almost 244 m2 of surface and is installed in batteries of 5 units.
The system is mounted on the floor, because of the lack of space over the roofs.
|
|
Operation / Performance |
|
|
Recommendations |
Nowadays, most industrial companies have green or environmentally friendly programs to improve their impact and improve their public image, in addition to improve the energy bills in case of renewable energies or energy efficiency. For this reason, the solar heat could be a safe investment if they want to fulfil the goals proposed.
|
|
|
|
|
|
|
|
|
|