General information |
|
|
Name |
Alpino S.A.
|
|
Country installed |
Greece
|
|
Address |
Thessaloniki, Greece
|
|
Industry sector, NACE code |
C10.5 - Manufacture of dairy products
|
|
Solar thermal system owner / operator |
Alpino S.A.
|
|
Solar thermal engineering company |
Sunny S.A.
|
|
Process integration engineering company |
|
|
Year of operation start |
1999
|
|
|
Technical parameters |
|
|
Collector technology |
flat plate collector
|
|
Collector name |
|
|
Installed collector area (gross), m² |
740.0
|
|
Installed collector area (aperture), m² |
|
|
Installed collector area (absorber), m² |
|
|
Installed thermal power (estimated), kWth |
518.0
(Default value calculated by multiplying the gross collector area by 0.7 kWth/m²)
|
|
Solar collector loop heat transfer fluid |
water/glycol
|
|
Solar energy storage |
short-term water storage
|
|
Storage volume, m³ |
25.0
|
|
Kind of conventional heat source |
steam boiler
|
|
Kind of fuel used |
fuel oil
|
|
|
Process |
|
|
Solar thermal energy used for |
hot water preheating in steam boiler
|
|
Unit operation |
general process heating
|
|
Point of Solar Heat Integration |
A3) Heating of supply heat storage
|
|
--> Integration how and where |
The hot water from the closed-loop hydraulic circuit of the two branches of the flat solar collectors heats (through an internal heat ex-changer) the water in two closed storage tanks. Тhe hot water leaving the storage tanks is then used for the pre-heating of the water that enters the steam boiler.
|
|
--> Temperature range process |
20-70 °C
|
|
--> Temperature range solar loop (min/max), C° |
|
|
|
Economic parameters |
|
|
Total investment costs (excl. VAT), € |
1.00
(Turnkey costs including solar collectors, piping, support construction, storage, design, commissioning reduced with subsidies)
|
|
Solar loop (excl. VAT), € |
(Solar collectors, piping, support construction)
|
|
Solar energy storage (excl. VAT), € |
|
|
Others (excl. VAT), € |
(Design, commissioning, others)
|
|
Process integration (excl. VAT), € |
|
|
Subsidy, € or % of total investment costs |
no subsidies
|
|
Cost for fuel replaced, €/MWhfuel |
|
|
Calculated solar thermal system life time, a |
0
|
|
Annual useful solar heat delivery, MWh/a |
|
|
Specific annual useful solar heat delivery, MWh/am² |
|
|
Specific investment costs, €/m² |
0.0
|
|
Solar fraction, % |
|
|
|
Lessons learned |
|
|
Initiative |
|
|
Integration methodology |
|
|
Crucial Interfaces |
|
|
Construction / Commissioning |
|
|
Operation / Performance |
|
|
Recommendations |
|
|
|
|
|
|
|
|
|
|